Ag-leader Yield Monitor 2000 Quick Reference Sheets User Manual

Browse online or download User Manual for Equipment Ag-leader Yield Monitor 2000 Quick Reference Sheets. Ag Leader Yield Monitor 2000 Quick Reference Sheets User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Yield Monitor 2000 – QUICK REFERENCE SHEET – September 1996
Setting Moisture to Manual or Automatic
STEP ACTION
1. Display the load to be changed.
2. Press MOIST key to get “MOIST=MAN or AUTO”
3. Press UP or DOWN ARROW key to change.
If set to MAN (building on sensor< AUTO reads high)
4. Press MOIST key to get “xx.x AVG %”.
5. Press UP or DOWN ARROW key to set AVG % moisture for load.
Logging Map Data to a Memory Card
STEP ACTION
1. Press SETUP key to get “LOGGING DEVICE=
2. Press UP ARROW KEY TO SET ON? M CARD”.
3. Press SET key to get “x SEC LOGGING INTERVAL
4. Press UP or DOWN ARROW key to set on 1,2 or 3 seconds.
5. Press SETUP key to get “LOG W/O GRAIN FLOW=”.
6. Press UP or DOWN ARROW key to set on :
NO for combine use Yes for tractor use
7. Copy Memory to Backup/Card before reading card into computer.
Arrow at right end of top display points to card when logging.
Should see DG Æ when logging. (D+ differential signal, G= GPS signal)
Coping Memory to Backup/Card
STEP ACTION
1. Press MEM key to get “COPY MEMORY TO BACKUP?.
2. Press YES key (Copies memory to card first, if card installed).
-or-
3. Shut monitor off to get “COPY MEMORY TO BACKUP?”.
4. Press YES key (Copies memory to card first, if card installed).
-or-
5. Press MEM key to get “COPY MEMORY TO CARD?.
6. Press YES key (Copies memory to card only)
Area Count Light: OFF – Counting acres. ON – Not counting acres
Calibrating Moisture
STEP ACTION
1. Harvest a load of grain.
2. Use reference tester to measure moisture (average many samples).
3. Display load on which moisture was checked.
4. Press MOIST key to get “xx.x AVG%”.
5. Use UP or DOWN ARROW key to set actual moisture value.
You must calibrate for each grain type.
Adjusting one load affects all loads for that grain type.
Setting Swath
STEP ACTION
1. Display a load of desired grain type
2. Press ROW SPACE key.
3. Press Up or DOWN ARROW key to set row spacing.
4. Press # ROWS key.
5. Press RIGHT ARROW key to move cursor under xx ROW HEAD.
6. Press UP or DOWN ARROW key to set # head rows.
Setting Partial Swath (Point rows)
7. Press # ROWS or SWATH key.
8. Press DOWN ARROW key to reduce rows or swath CUT.
9. Press UP ARROW to set rows or swath CUT up after partial swath.
Swath is always # Rows x ROW SPACE. Use 6” or 12 spacing to set swath in
1/2 foot or 1 foot increments when cutting non-rowed crops.
Setting Stop Height
STEP ACTION
1. Change to Data Load (LxÆ) of desired grain type.
2. Press STOP HEIGHT key.
3. Position header at height to shut off acre counting.
4. Put the Area Count Switch in the up position.
If Area Count Light is off If the Area Count Light in on
5. Press DOWN ARROW key to
decrease stop height number until
light is on.
Press UP ARROW to increase
stop height number until light is
off. Decrease number until light
is on.
Page view 0
1 2

Summary of Contents

Page 1

Yield Monitor 2000 – QUICK REFERENCE SHEET – September 1996 Setting Moisture to Manual or Automatic STEP ACTION 1. Display the load to be changed.

Page 2

Yield Monitor 2000 – QUICK REFERENCE SHEET – September 1996 Changing/Starting Fields STEP ACTION 1. Press FIELD key. 2. Press UP or DOWN ARROW key

Comments to this Manuals

No comments