Installation Instructions: NMEA Output Cable – EZ-Guide 250
1. Remove the orange wedgelock from cable p/n 4001424 (TNL p/n 65168) or p/n 4001441 (TNL p/n 64228) using
needle-nose pliers. Pull wedgelock straight out.
2. Hold connector with rear grommet facing you.
3. Remove the plastic inserts from cavity’s 5, 6, and 7
4. Insert the Yellow wire of cable p/n 4001444 (TNL p/n 63076) into cavity 5.
5. Insert the Violet wire of cable p/n 4001444 (TNL p/n 63076) into cavity 6.
6. Insert the Green wire of cable p/n 4001444 (TNL p/n 63076) into cavity 7.