Yield Monitor 2000
System Wiring
Ag Leader Technology
June 1997
7-11
Checking Header
Sensor
Connections
To check the header sensor for electrical connection, use an ohmmeter and
check for the following resistance’s:
Check at: Pins Ohms
Cab Cable (rectangular 25 pin conn.) 11 + 18 100-200
Cab Cable (rectangular 25 pin conn.) 10 + 18 700-1000
Cab Cable (rectangular 25 pin conn.) 10 + 18 1000
Distribution Cable (large round 24 pin conn.) 10 + 16 100-200
Distribution Cable (large round 24 pin conn.) 9 + 16 700-1000
Distribution Cable (large round 24 pin conn.) 9 + 10 1000
Header Sensor Cable (rectangular 3 pin conn.) A + B 100-200
Header Sensor Cable (rectangular 3 pin conn.) B + C 700-1000
Header Sensor Cable (rectangular 3 pin conn.) A + C 1000
* * *