Starting, Naming Fields, Loads
Yield Monitor 2000
Ag Leader Technology
June 1997
2-30
Starting, Naming
Loads With the
Monitor
The next step is to create and name the loads within the fields. You need to
consider how you want to logically subdivide the fields into loads.
Note: It is common to designate Load 1 for the end rows and name it
“ENDROWS”. The other loads could be designated for a certain variety or
hybrid. Name these loads the hybrid or variety name (example:
“L2:P3417”). Because you may not know how many loads you want to
create until harvest, you can create and name more loads any time.
Step Action
1 Press the LOAD key to display field and load on the top line.
2 With the cursor under the load, use the RIGHT ARROW key to
move the cursor to the right one space.
3 Press the top-right UP ARROW key to change the blank space to
either a symbol, number, or letter. You can enter up to eight
characters for a load name.
Example:
F1:WEST8 L1:HYBRID
CORN 0.0 AV B/A
4 Press the LOAD key to display field and load on the top line to
create a load.
5 Press the top-right UP ARROW key to scroll to the next load. If
the next load has not already been created, the monitor displays
“START NEW LOAD?” on the top line.
6 Press the YES key to start a new load.
7 Name the new load and create and name loads for all the fields you
have created.
8 Repeat steps 1 through 7 for each field you want to create.
Settings Performed
in the Combine
All the settings up to this point could be completed with the monitor out of
the combine and plugged into a wall outlet. The stop height setting and the
distance calibration must be completed with the monitor in the combine cab.
* * *