Ag-leader Yield Monitor 2000 Operators Manual User Manual Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
Calibrating Grain Weight
Yield Monitor 2000
Ag Leader Technology
June 1997
3-16
Step Action
4
If the… Then…
Maximum error is +/- 15
percent or higher and
“CONTINUE WITH LBS
CAL?” is displayed
Press the NO key and then hit any key
to advance through each calibration
load and its calibration error. Write
down the calibration loads and errors
of loads with errors of +/- 15 percent
or higher.
Maximum error is +/- 15
percent or higher and
“PRESS ANY KEY TO
CONTINUE” is displayed
Press any key to advance through each
calibration load and its calibration
error. Write down the calibration loads
and errors of loads with errors of +/-
15 percent or higher.
Maximum error is less than
+/- 15 percent
If you have 4 or more actual weights,
CONTINUE WITH LBS CAL? will be
displayed. Press the YES key to
continue with the full calibration and
go to step 8, otherwise PRESS ANY
KEY TO CONTINUE will be
displayed and the errors you have are
your final errors until you can enter 4
or more actual weights and fully
complete the calibration.
Notes:
If you do not want to scroll through all the calibration loads, you
can press the NO key and the monitor returns to its normal
display.
Example:
An example of a calibration load and its error is “F2/L1 +1.0%
ERROR”. This means that the weight of the grain that the monitor
measured in field 2 load 1 is +1.0% higher than the actual weight that
was entered for that load.
5 If you find calibration loads with calibration errors of higher than +/-
15 percent, display those loads, one at a time, on the top line and
check the following:
Is the grain type correct for this load?
Is the moisture reasonable for this grain type and field?
Is the actual lbs value correct for this load?
Page view 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 201 202

Comments to this Manuals