Yield Monitor 2000
Moisture Setting
Ag Leader Technology
June 1997
2-21
Setting/Changing
Moisture
The monitor can be set on automatic moisture to receive readings from the
moisture sensor or manual moisture to use an average moisture for each
load. The monitor comes from the factory set on automatic moisture.
Follow these steps to set the moisture setting.
Note: Any new loads you create will have the same moisture setting as that
of the last load in the same field. Make sure all of the existing loads are set
on automatic moisture.
Step Action
1 Press the LOAD key to display a load on the top line of the display.
2 Press the MOIST key until “MOIST=AUTO or MAN” appears on
the display.
3 Use the bottom-left UP or DOWN ARROW key to select AUTO or
MAN.
4 If you set MOIST=MAN, you must enter an average moisture value
for that load. Press the MOIST key until “xx.x AVG %” appears on
the display.
5 Use the bottom-left UP or DOWN ARROW keys to set an average
moisture value for that load.
Buildup on the
Sensor
The moisture sensor can give readings that are too high if sticky material
from weeds or green stems buildup on the moisture sensor. This is normally
only a problem in soybeans with a lot of weeds or green stems. If you have
high moisture readings from buildup, remove the moisture sensor and clean
it. After cleaning, continue harvesting. If the buildup condition is severe,
you may not be able to keep the moisture sensor clean. In such conditions,
set the moisture for the load on manual and enter the average moisture for
that load as instructed above. After buildup conditions cease, set the
moisture back to automatic.
* * *