Calibrating Distance
Yield Monitor 2000
Ag Leader Technology
June 1997
3-2
Preparing to
Calibrate Distance
You must do the following before you begin calibrating distance:
Accurately measure a known distance, setting flags or making a mark at
each end
Notes:
A distance of at least 200 feet is desired to obtain an accurate
calibration.
For maximum accuracy, calibrate on a ground surface that is at least
somewhat similar to field conditions (you can also calibrate while
harvesting if you know or measure a precise distance in the field).
Change to a data load (load with arrow to right of load number L1->)
with no distance.
Follow these procedures to change to a data load.:
Step Action
1
Start a new load by pressing the top UP ARROW key with the
load displayed and scroll past the last load.
or
Make an existing load the data load by pressing the MEM key
until “CHANGE TO THIS LOAD?” appears on the display, then
press the YES key.
2 Press the DIST key to display “x FT,” and check that 0 feet are in the
data load. If there are feet in the load, start a new load according to
step 1.