Calibrating Distance
Yield Monitor 2000
Ag Leader Technology
June 1997
3-4
Step Action
7 Use the lower-right UP or DOWN ARROW key to increase or
decrease the number of feet displayed so that it is equal to the
distance measured.
Notes:
When you change the feet measurement on the display, you are
changing the distance calibration number. You can see the
number if you press the DIST key until “xxxxpls/100’ “ appears
on the display.
It may take several increment or decrement cycles to go from
where the measured distance is 1 foot under to 1 foot over the
measured distance. Count the number of beeps and set it in the
middle of this range.
Clearing Feet Out
of the Load
Follow these procedures to clear the feet out of the load:
Step Action
1 Press the MEM key until “CLEAR DATA IN THIS LOAD?”
appears on the display.
2 Press the YES key.
3 After the Monitor beeps four times and “ARE YOU REALLY
SURE? YOU WILL LOSE DATA” appears on the display, press
the YES key again.
4 If you are using a GPS receiver for ground speed, change the
“SPD=” setting back to the correct GPS setting for that load.
Calibrating
Distance
Accurately
Turn the combine around and repeat the above steps for calibrating distance
and clearing feet out of the load until you are confident that you have set the
distance calibration as accurately as you can.
Note: Perform this check while traveling forward only because combine